Our product range includes a wide range of e+e elektronik ee8915 co2 sensor for railway applications, e+e elektronik ee800 room sensor for co2, temperature, and relative humidity, e+e elektronik ee850 co2, humidity and temperature duct sensor, co2 carbon di oxide sensor, modular 4 in 1 probe for co2 humidity temperature and pressure (ee872) and miniature-sensor module for co2 temperature and barometric pressure (ee895).






₹ 50000 / PieceGet Latest Price
| Measuring range | 0 to 10000 ppm |
| Sensor type | NDIR |
| Output signal | 4 to 20 mA |
| Mounting | Wall mount |
| Supply voltage | 24 V DC |
| With temp sensor | Yes |
| Ingress rating | IP65 |
| Display type | No display |
| Calibration | Manual |
EE8915 measures reliably CO₂ concentration in harsh environment and complies with the relevant railway standards. Active pressure and temperature compensation with on-board sensors leads to best CO₂ measurement accuracy independent of temperature, altitude or weather conditions.



₹ 40000 / PieceGet Latest Price
| Measuring range | 0 to 5000 ppm |
| Sensor type | NDIR |
| Output signal | 4 to 20 mA |
| Mounting | Wall mount |
| Supply voltage | 24 V DC |
| With temp sensor | Yes |
| Ingress rating | IP65 |
| Display type | LED |
| Relay outputs | 3 relays |
| Calibration | Manual |




₹ 40000 / PieceGet Latest Price
| Measuring range | 0 to 10000 ppm |
| Sensor type | NDIR |
| Output signal | RS485 |
| Mounting | Duct mount |
| Supply voltage | 24 V DC |
| With temp sensor | Yes |
| Ingress rating | IP65 |
| Display type | No display |
| Relay outputs | 3 relays |
| Calibration | Manual |
The EE850 combines CO2 and temperature (T) measurement in an innovative enclosure. It is ideal for demand controlled ventilation and building automation. With a CO2 measuring range of up to 10 000 ppm and a T working range of -20...+60 °C (-4...+140 °F), the EE850 can be employed also in demanding climate and process control applications. The EE850 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.






₹ 10000 / PieceGet Latest Price
| Suitable Media | Gas |
| Output | Bipolar LO |
| Supply Voltage | 30 V DC |
| Operating Temperature | -20 Degree Celsius to +55 Degree Celsius |
| Material | Plastic |
| Storage Temperature | -30 Degree Celsius to +75 Degree Celsius |
| Sensing Mode | 640 nm Visible Red |
| Repeatability | 125 microsecond |









Get Latest Price
| Measuring range | 0 to 10000 ppm |
| Sensor type | High-end capacitive humidity sensing |
| Output signal | 4 to 20 mA |
| Mounting | Probe type |
| Ingress rating | IP65 |
| Display type | No display |





Get Latest Price
| Measuring range | 0 to 10000 ppm |
| Sensor type | NDIR |
| Output signal | 4 to 20 mA |
| Mounting | PCB mount |
| Supply voltage | 24 V DC |
| Ingress rating | IP65 |
| Display type | No display |
A Single Module - 3 Measurands
The EE895 module measures not only the CO₂ concentration up to 10,000 ppm (1% CO₂) but also the temperature (T) and ambient pressure (p). The pressure and temperature compensation with on-board sensors minimizes the impact of the environment onto the CO₂ measurement. As a result, the EE895 offers a particularly high CO₂ measurement accuracy, independent of altitude or changing ambient conditions.
Long-Term Stable CO₂ Measuring Principle
The dual wavelength NDIR CO₂ measuring principle with auto-calibration ensures excellent long-term stability, as it automatically compensates for aging effects and is particularly resistant to contamination. The multi-point CO₂ and temperature factory adjustment procedure leads to excellent CO₂ measurement accuracy over the entire T working range from -40...60 °C (-40...140 °F).
Easy Design-In
The I²C and UART interfaces, the very small dimensions of only 35 mm x 15 mm x 7 mm (1.38" x 0.6" x 0.27") and various mounting options facilitate the design-in of the sensor module.
Flexibly Configurable
The EE895 module can be configured via the digital interface. The CO₂ measurement interval can be set according to the application and the power requirements.
EE895 Evaluation Board for Test Purposes
The evaluation board, which is available as an accessory, allows easy testing of the EE895 with a view to the intended application. It is connected to the PC via a USB cable. Using the sensor evaluation software, which is available free of charge, the measurement data can be visualised and logged. Users have the option to set the EE895's measurement interval, and the desired measurement units for temperature and pressure.
Design Data and Support Literature
The electronic design data of the EE895 is available free of charge from the download area of the E+E website. This means that the 3D data from the sensing module can be quickly and easily transferred to a CAD design tool. Using the I²C interface, the EE895 module can be connected to various single board computers such as the Arduino or Raspberry Pi. Step-by-step instructions (available from the download area) help you program and integrate the EE895 into your application.
Typical Applications







Get Latest Price
| Measuring range | 0 to 5000 ppm |
| Sensor type | NDIR |
| Output signal | 4 to 20 mA |
| Mounting | Wall mount |
| Supply voltage | 24 V DC |
| Ingress rating | IP54 |
| Display type | LCD |
| Relay outputs | 2 relays |
Outstanding Measurement Performance
The CO2 measurement of the CDS201 relies on the pollution-resistant E+E dual wavelength NDIR technology. This measuring principle automatically compensates for ageing effects and ensures excellent long-term stability. The multiple point CO2 and temperature adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range.
The E+E proprietary sensor coating protects the RH/T sensing element from contamination and corrosive deposits. This improves the measuring performance and service life of the sensing element in dusty or dirty environments.
Outputs and Digital Interface
The CDS201 room sensor features analogue outputs or RS485 interface with Modbus RTU. In the digital version, the CDS201 also calculates the dew point temperature (Td). The measured values can also be read locally on the optional graphic display.
The version with RS485 interface can be set up and configured via PC with the free PCS10 Product Configuration Software and an optional configuration adapter.
Installation-friendly Enclosure
The enclosure of the CDS201 facilitates fast and thus cost-saving installation. The back cover with the push-in spring terminals can be mounted and wired without the front cover. This means that the electronics, which are accommodated in the front cover, are not exposed to construction site pollution. Before commissioning, the active part can be simply snapped onto the back cover. Besides, the electronics part can be replaced without tools within seconds.
Typical Applications






Get Latest Price
| Measuring range | 0 … 20 m/s (0 … 4000 ft/min) |
| Sensor type | Thermal mass (calorimetric) sensor |
| Output signal | RS485 |
| Mounting | Wall mount |
| Supply voltage | 24 V DC |
| With temp sensor | Yes |
| Ingress rating | IP65 |
| Display type | LCD |
| Relay outputs | 2 relays |
The Sigma 05 sensor hub represents the central element of the E+E modular sensor ecosystem with intelligent probes, analogue outputs and display. With pluggable, interchangeable probes, the modular sensor platform is suitable even for harsh and challenging environment. The Sigma 05 is available with polycarbonate or die-cast aluminium enclosure.
Inquire nowTo the downloadsFlexibility: Multiple Probes and Measurands
The Sigma 05 accommodates up to 3 E+E sensing probes with RS485 interface and Modbus RTU protocol. Up to 5 measurands can be assigned to the two freely selectable and scaleable analogue outputs and to the optional graphic display.
Plug-and-Play
Sigma 05 features automatic detection of E+E probes and performs an autonomous, rule based hub setup. Refer to the user manual for details.
Configuration and Adjustment
The free PCS10 Product Configuration Software allows for easy setup of the Sigma 05, measurand assignment and thresholds, display layout, scaling of the analogue outputs and adjustment of the connected probes.
Available Sensing Probes for Sigma 05
EE072 - Humidity and Temperature Probe
EE074 - Temperature Probe
EE671 - HVAC Air Velocity Probe
EE680 - Air Velocity and Temperature Sensor for Laminar Flow
EE872 - Modular Probe for CO₂, Humidity, Temperature and Ambient Pressure
HTP501 - Digital Humidity and Temperature Probe
MOP301 - Insertion Moisture in Oil Probe with Modbus RTU
Reference Probe
A functional and accuracy check of the Sigma 05 can be performed with the E+E Reference Probe Modbus RTU instead of the regular sensing probes. The reference probe supplies fixed values for a wide choice of measurands and features an individual certificate. Refer to the Reference Probe Modbus RTU Quick Guide for further details.
We are always available to answer any questions you may have!


₹ 45000 / PieceGet Latest Price
| Brand | EE |
| Model No. | EE872 |
| Measuring Range CO2 | 0 To 3 % (30000 ppm) |
| Accuracy CO2 - MV - Measured Value | +- (1.5 % From Full Scale + 2 % mv) |
| Measuring Range Relative Humidity | 0 To 95 % RH (non condensing) |
| Accuracy Relative Humidity | typ. +- 3 % RH |
| Measuring Range Pressure | 700 To 1100 mbar (10.15 To 15.95 psi) |
| Accuracy Pressure At 25 Degree Celsius | typ. +- 2 mbar |
| Measuring Range Temperature | -40 To 60 Degree Celsius (-40 To 140 Degree Fahrenheit) |
| Output Analogue | 0-5V / 10 V and 0/4-20 mA |



₹ 20000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Brand | EE |
| Model Name/Number | EE10 |
| Display Type | Digital |
| Accuracy | +-2% RH |
| Measuring Range | 0 To 95% RH |
| Outputs | 0-10 V 4-20 |
| Voltage Supply | 24 V AC/DC |



₹ 20000 / PieceGet Latest Price
| Measuring Range | 0 To 2000 ppm / 0 To 5000 ppm / 0 To 10000 ppm |
| Brand | EE |
| Model No. | EE8915 |
| Accuracy - MV - Measured Value | <+- (100 ppm +5% of mv) |
| Outputs | 10V and 0 / 4-20mA |
| Power Supply Range | 10-35 V DC |






Get Latest Price
| CO2 range | 0-10000 ppm |
| Meter type | Element |
| Measured parameters | CO2;Temp;RH, CO2 |
| Sensor type | Electrochemical |
| Output interface | Modbus RS485 |
| Power supply | 24V DC, 24V AC |
The dual wavelength NDIR technology with auto-calibration is particularly long-term stable and insensitive to contamination. A multiple point CO₂ and T factory adjustment leads to excellent CO₂ measurement accuracy over the entire T working range. The pressure compensation minimizes the impact of altitude and ambient pressure variations onto the CO₂ readings.
The measured data, with a range of up to 1% CO₂, is available on the I²C or the E2 digital interface. Small dimensions and electrical connection via contact pins, edge card socket or pads facilitate the design-in.
The CO₂ measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to 420 μA, ideal for battery-operated devices.
Typical Applications



Get Latest Price
| Outputs | 0-5 / 10V and 0 / 4-20mA |
| Measuring range | 0...2000 ppm 0...5000 ppm 0...10000 ppm |
| Accuracy - *mv - measured value | <+- (50 ppm +2% of mv) <+- (50 ppm +3% of mv) <+- (100 ppm +5% of mv) |
| Supply | 10-35 V DC |
| Key Features | E+E dual wavelength NDIR working principle |
| Compliance with railway standards | EN50155:2017- Electronic equipment used on rolling stock EN50121-1:2017 - Electromagnetic compatibil |


Get Latest Price
| Output analogue | 0-10 V or 4-20 mA |
| Supply | 24V AC/DC |
| Temperature Dependency | Very low temperature dependency |
| Configuration | Easy user configuration and adjustment |
| Installation | Fast and easy installation |



Get Latest Price



Get Latest Price

Get Latest Price
| Measuring range Humidity | 0...95 % RH |
| Measuring range Temperature | -20...60 DegreeC (-4...140 DegreeF) |
| Accuracy Humidity | +-3 % RH (20...80 % RH) |
| Output analogue | 0-5 / 10 V or 4-20 mA |
| Supply | 24 V AC/DC |
| Accuracy Temperature | +-0.3 DegreeC (+-0.54 DegreeF) |
| Output digital | Modbus RTU |

Get Latest Price

Get Latest Price
The E+E CO₂ sensors feature the dual wavelength/dual detector NDIR principle. One detector is tuned to 4.2 µm wavelengths, which is absorbed by CO₂, the second detector on 3.9 µm, which is not affected by any gas. For every single measurement the CO₂ concentration is calculated from the outputs of the two detectors.
This procedure is highly insensitive to pollution and appropriate for both HVAC and industrial process control.
A multiple point CO₂ and temperature adjustment procedure leads to excellent CO₂ measurement accuracy over the entire temperature working range.
Several E+E CO₂ measuring devices feature also temperature, humidity and barometric pressure measurement.
Product Range
Applications

Get Latest Price



₹ 30000 / PieceGet Latest Price
| Measuring range | 0 to 10000 ppm |
| Sensor type | NDIR |
| Output signal | 4 to 20 mA |
| Mounting | Wall mount |
| Supply voltage | 24 V DC |
| With temp sensor | No |
| Ingress rating | IP54 |
| Display type | LED |
| Relay outputs | 2 relays |
| Calibration | Manual |
The EE820 CO2 sensor is optimized for use in harsh, demanding applications, such as hatchers, incubators, life stock barns or greenhouses.
Mr. Ankush Bhandari (Managing Director)
E+E Elektronik India Private Limited
801, Lodha Supremus, Andheri E, Sakhi Vihar Road, Opposite Mtnl Office, Mumbai - 400072, Maharashtra, India